Kayden CLASSIC® 810 Flow, Level, Interface Switch & Transmitter
Brand: Kayden InstrumentsThe Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter features a precision welded, highly accurate stainless steel sensor. Ideal for liquids, gases & slurries in a clean or dirty process, and is available in a wide range of thread sizes and insertion lengths.
All Kayden models feature a rugged flameproof enclosure with blind or lens covers available. Kayden’s advanced digital electronics will revolutionize the way you monitor and control your process.
- Process Connections - Male NPT
- 1/2"
- 3/4"
- 1"
- 1-1/4"
- 1-1/2"
- 2"
- Adjustable Set Point Range
- 0-254 feet/s, 0-77 meters/s
- Insertion 'U' Lengths
- 1.2" (3.0 cm)
- 2" (5.0 cm)
- 3" (7.5 cm)
- 4" (10.1 cm)
- 6" (15.2 cm)
- 9" (22.8 cm)
- 12" (30.4 cm)
- 18" (45.7 cm)
- Custom Lengths from 2.5" to 120" (6.0 cm to 305 cm) by 1/2" (1 cm) increments
- Input/Supply Power
- 12-24 Vdc & 120-240 Vac, 50-60 Hz
- Operating Pressure (Maximum)
- CSA & FM: 3,480 psi, 24,000 kPa, 240 bar
- CRN - 316/316L Stainless Steel - Canadian Registration Number 0F20731.5C: 2,053 psi, 14,155 kPa, 142 bar
- CRN - Titanium - Canadian Registration Number 0F20731.5C: 1,165 psi, 8,033 kPa, 81 bar
- CRN - Hastelloy C-276 - Canadian Registration Number 0F20731.5C: 2,290 psi, 15,790 kPa, 158 bar
- Temperature Range (Sensor)
- -45° to 200° C, -50° to 392° F
- Local Enclosure
- Aluminum Flameproof
- 1" Female NPT
- NEMA 4X, IP55 / IP67
- Local Enclosure Cover
- Blind or Glass Lens
- Flameproof
- Wetted Materials
- 316/316L Stainless Steel
- Titanium
- Hastelloy C-276
- Outputs/Communications
- Two Independent Relays (SPDT)
- 4-20 mA
- Modbus
- Rated 120 Vac max, 30 Vdc max, 4 A max
- Approvals
- FM
- CSA
- CRN
- Single Seal
- NACE
- ASME BPVC Sec. VIII Div. 1
Displaying price & availability for United States in USD Change Location or currency.
908 models matching criteria
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 109 cm U, SST, Lens Cover, CSA, CRN
25+ In Stock
$677.93USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 24 cm U, SST, Lens Cover, CSA, CRN
50+ In Stock
$170.27USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 103 cm U, SST, Lens Cover, CSA, CRN
50+ In Stock
$204.01USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 3" U, SST, Blind Cover, CSA
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: 3", 7.62 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), Single Seal, NACE, NEMA 4
50+ In Stock
$247.95USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 8" U, SST, Blind Cover, CSA, CRN
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: Custom 8", 20.32 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
50+ In Stock
$256.58USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 126 cm U, SST, Lens Cover, CSA, CRN
50+ In Stock
$345.24USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 6.5" U, SST, Blind Cover, CSA, CRN
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: Custom 6.5", 16.5 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
50+ In Stock
$352.30USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 9" U, SST, Blind Cover, CRN
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: 9", 23 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (AB, SK, ONT), Single Seal, NACE, NEMA 4
50+ In Stock
$407.23USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 24" U, SST, Lens Cover, CSA
show more
- Process Connections: 2" MNPT
- Insertion 'U' Length: 24", 60.9 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminum Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
50+ In Stock
$452.74USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 2" U, SST, Remote Electronics, Blind Cover, CSA
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: 2", 5.0 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Flameproof Blind Cover
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software) Downloadable from
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), Single Seal, NACE, NEMA 4
50+ In Stock
$478.63USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/2" NPT, 2" U, SST, Blind Lens Cover, FM
show more
- Process Connections: 1-1/2" MNPT
- Insertion 'U' Length: 2", 5.0 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Flameproof Blind Cover
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- FM, NACE, NEMA 4
50+ In Stock
$496.68USD
$19.99 Shipping
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 12"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: CRN
show more
- Sensor Material - 316/316L Stainless Steel
- Process Connection - Male NPT - 1/2"
- Insertion 'U' Length - 12" (30 cm)
- Cover for Local Enclosure - Glass Lens Cover
- Remote Electronics Enclosure & Cover - Not Required
- Agency Approvals - CRN & CSA (Canada)
50+ In Stock
$525.71USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 1.2" U, Hastelloy-C, Lens Cover, FM
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: 1.2", 3.0 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Hastelloy C-276 Sensor
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- FM, NACE, NEMA 4
50+ In Stock
$553.17USD
$19.99 Shipping
50+ In Stock
$597.90USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 12.5" U, SST, Lens Cover, CSA
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: Custom 12.5", 31.75 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software) Downloadable from
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), Single Seal, NACE, NEMA 4
50+ In Stock
$628.50USD
$19.99 Shipping
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 12"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)
50+ In Stock
$655.18USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 5.5" U, SST, Blind Cover, CSA, CRN
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: Custom 5.5", 14 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
50+ In Stock
$662.24USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/2" NPT, 20" U, SST, Lens Cover, CSA, CRN
show more
- Process Connections: 1-1/2" MNPT
- Insertion 'U' Length: 20", 50.8 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 1165 psi, 8032 kPa, 80.3 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, CRN, Single Seal, NACE, NEMA 4
50+ In Stock
$718.73USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 3.5" U, SST, Lens Cover, CRN
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: Custom 3.5"
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software) Downloadable from
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (Canada), Single Seal, NACE, NEMA 4
50+ In Stock
$763.46USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 30" U, SST, Lens Cover, CRN
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: Custom 30", 76.2 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (AB, SK, ONT), Single Seal, NACE, NEMA 4
25+ In Stock
$85.53USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/2" NPT, 1.2" U, SST, Blind Cover, CSA
show more
- Process Connections: 1-1/2" MNPT
- Insertion 'U' Length: 1.2", 3.0 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$102.79USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/2" NPT, 3" U, SST, Blind Cover, CSA
show more
- Process Connections: 1-1/2" MNPT
- Insertion 'U' Length: 3", 7.5 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -50°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316 Stainless Steel, Other Materials Available
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$180.47USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/4" NPT, 24" U, SST, Lens Cover, CSA
show more
- Process Connections: 1-1/4" MNPT
- Insertion 'U' Length: 1.2", 3.0 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminum Flameproof, 1" FNPT
- Cover: Flameproof Glass Cover
- Remote Electronics Enclosure and Cover: Not Selected
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$214.21USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 300 cm U, SST, Lens Cover, CRN
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: Custom 300 cm, 118.1"
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (AB, SK, ONT), Single Seal, NACE, NEMA 4
25+ In Stock
$234.61USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 24" U, SST, Lens Cover, CSA
show more
- Process Connections: 2" MNPT
- Insertion 'U' Length: 24", 60.9 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminum Flameproof, 1" FNPT
- Cover: Flameproof Glass Cover
- Remote Electronics Enclosure and Cover: Not Selected
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$292.67USD
$19.99 Shipping
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 7"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: CRN/CSA
show more
- Sensor Material - 316/316L Stainless Steel
- Process Connection - Male NPT - 1/2"
- Insertion 'U' Length - 7 Custom 'U' Length: Inches
- Cover for Local Enclosure - Glass Lens Cover
- Remote Electronics Enclosure & Cover - Not Required
- Agency Approvals - CRN & CSA (Canada)
25+ In Stock
$337.40USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 4" U, SST, Remote Electronics, Lens Cover, FM
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: 4", 10.1 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminum Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- FM, NACE, NEMA 4
25+ In Stock
$342.89USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2" U, Hastelloy-C, Lens Cover, CSA
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: 2", 5.0 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Hastelloy C-276 Sensor
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$361.72USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 100 cm U, SST, Lens Cover, CRN
25+ In Stock
$382.12USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 4" U, Hastelloy-C, Blind Cover, CSA
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: 4"
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Hastelloy C-276 Sensor
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software) Downloadable from
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), Single Seal, NACE, NEMA 4
25+ In Stock
$393.11USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 20" U, SST, Blind Cover, CSA
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: Custom 20", 50.8 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standard), Single Seal, NACE, NEMA 4
25+ In Stock
$433.12USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6" U, Hastelloy-C, Remote Electronics, FM
show more
- Sensor Material - Hastelloy® C-276
- Process Connection - Male NPT - 1/2"
- Insertion 'U' Length - 6" (15.2 cm)
- Cover for Local Enclosure - Blind Cover
- Remote Electronics Enclosure & Cover - Glass Lens Cover
- Agency Approvals - FM
25+ In Stock
$480.20USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/2" NPT, 10.5" U, SST, Lens Cover, CSA, CRN
show more
- Process Connections: 1-1/2" MNPT
- Insertion 'U' Length: Custom 10.5",
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 1165 psi, 8032 kPa, 80.3 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminum Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, CRN, Single Seal, NACE, NEMA 4
25+ In Stock
$514.73USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2" U, Titanium, Lens Cover, CSA
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: 2", 5.0 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Titanium Gr. 2 Sensor
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$520.22USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 305 cm U, SST, Lens Cover, CSA, CRN
25+ In Stock
$552.39USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2" U, SST, Lens Cover, FM
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: 2", 5.08 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- FM, NACE, NEMA 4
25+ In Stock
$572.79USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 4" U, SST, Lens Cover, CRN
show more
- Process Connections: 3/4" MNPT
- Insertion 'U' Length: 4", 10.16 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
25+ In Stock
$579.07USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 2" U, SST, Remote Electronics, Blind Cover, CSA
show more
- Process Connections: 2" MNPT
- Insertion 'U' Length: 2", 5.0 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Blind Cover
- Remote Electronics Enclosure and Cover: Flameproof Blind Cover
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$586.13USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 3" U, SST, Lens Cover, CRN
show more
- Process Connections: 1" MNPT
- Insertion 'U' Length: 3", 7.62 cm
- Probe Width: 1.05" 2.66cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 608 psi, 4192 kPa, 41.9 bar
- Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316/316L Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT)
- 4-20 mA (Thermal Signal, Scalable)
- Modbus Communication via RS-485
- RCMS (Remote Control & Monitoring Software)
- Electronics - Standard Features:
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out
- Easy Set-up:
- No Mechanical Jumpers or Trim Pots
- Intelligent Push Button Interface
- Constant Display of Operation (Flow/Level)
- Temperature Compensation
- Start-Up Bypass Timer
- c CSA us (UL Standards), CRN (AB, SK, ONT), Single Seal, NACE, NEMA 4
25+ In Stock
$656.75USD
$19.99 Shipping
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 2" NPT, 20" U, SST, Lens Cover, CSA
show more
- Process Connections: 2" MNPT
- Insertion 'U' Length: 20", 50.8 cm
- Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
- Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
- Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
- Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F
- Local Enclosure: Aluminium Flameproof, 1" FNPT
- Cover: Flameproof Glass Lens Cover
- Remote Electronics Enclosure and Cover: Not Required
- Wetted Materials:
- Standard: 316 Stainless Steel
- Outputs/Communications:
- Two Independent Relays (SPDT), 4-20 mA, Modbus
- UL, CSA, Single Seal, NACE, NEMA 4
25+ In Stock
$687.35USD
$19.99 Shipping
Specifications
Brand
Accuracy
- Flow Service: ± 1.0% of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
- Level Service: ± 0.64 cm (0.25")
Applications
- Flow
- Interface
- Level
Approvals & Certifications
- CRN - 316, 316L Stainless Steel - Canadian Registration Number 0F20731.5C: 2053 psi, 14,155 kPa, 142 bar
- CRN - Hastelloy® C-276 - Canadian Registration Number 0F20731.5C: 2290 psi, 15,790 kPa, 158 bar
- CRN - Titanium - Canadian Registration Number 0F20731.5C: 1165 psi, 8033 kPa, 81 bar
- CSA - Local (Sensor) Enclosure Flameproof: Class I, Division 1, Groups B, C, D, Ex D IIB + H2 AEx D IIB + H2 (Class I, Zone 1, Group IIB + H2) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
- CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex D IIB + H2 AEx D IIB + H2 (Class I, Zone 1, Groups IIB + H2) Temperature Code: T3
- FM - Local (Sensor) Enclosure Flameproof: Class I, Division 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx D IIB + H2 Enclosure Typical 4/IP55
- FM - Remote Electronics Enclosure - Optional Flameproof: Class I, Division 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx D IIB + H2 Enclosure Typical 4/IP55
Communication
- Modbus RTU Communication-Alarms, Flow Status & Diagnostics
- RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software
Cover - for Local Enclosure
- Blind Cover - Flameproof
- Glass Lens Cover - Flameproof
Electronics - Standard Features
- *Configurable only from the Kayden RCM Software
- 100% Digital Design. Electronics are Environmentally Sealed
- 4-Adjustable Independent Switch Point Timers
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out*
- Easy Setup: No Mechanical Jumpers or Trim Pots
- Incrementally Adjustable Heater Power (5% Steps) with Automatic Over-Range Protection
- Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
- Start-Up Bypass Timer
- Temperature Compensation
- Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode
Enclosure Finish
- Powder-Coated Polyester TGIC
Enclosure, Body Details
- 1" NPT Female Conduit Connection
- Buna-N O-Ring on Cover
Enclosure, Body Material
- Copper-Free Aluminum (Does Not Exceed 0.4% Copper)
Environmental Protection
- IP55
- IP67
- NEMA 4X
Input Power
- 12-24 Vdc, 120-240 Vac, 50/60 Hz
- Power Consumption: Maximum
- Universal Power Input
Insertion 'U' Length
- 1.2" (3 cm)
- 12" (30 cm)
- 18" (46 cm)
- 2" (5 cm)
- 3" (7.5 cm)
- 4" (10.1 cm)
- 6" (15.2 cm)
- 9" (23 cm)
- Custom 'U' Lengths 2.5" to 120" (6.4 cm to 305 cm) Available in 1/2" (1.0 cm) Increments.
NPT Connection
- 1" NPT Male
- 1/2" NPT Male
- 1-1/2" NPT Male
- 1-1/4" NPT Male
- 2" NPT Male
- 3/4" NPT Male
Operating Pressure - Sensor
- CRN - All Process Connections - 316/316 Stainless Steel - Canadian Registration Number 0F20731.5C: Maximum
- CRN - All Process Connections - Hastelloy® C-276 - Canadian Registration Number 0F20731.5C: Maximum
- CRN - All Process Connections - Titanium - Canadian Registration Number 0F20731.5C: Maximum
- CSA - All Process Connections: Maximum
Operating Temperature - Electronics
- -55° to 65° C (-67° to 149° F)
Operating Temperature - Sensor
- -45° to 200° C (-50° to 392° F)
Output
- 4-20 mA (Thermal Signal, Scaleable) 120 Vac, Maximum
Principle of Operation
- Thermal, Calorimetric
Remote Control & Monitoring Software
- Adjust Relay Modes
- Adjust Set Points 1 & 2
- Load or Save User Settings
- Lock or Unlock the Display Panel to Protect the Settings
- Many Other Adjustable Features
- Modify Heater Settings to Optimize Response Time
- Monitor Operating Status
- Operated Via a Personal Computer Locally or from a Remote Control Center
- Visualize the Actions of the Process Via the Graphical Display
Remote Electronics Enclosure & Cover
- Blind Cover - Flameproof
- Glass Lens Cover - Flameproof
Response Time
- Approximately 0.5 to 30 seconds
Sensor, Probe Style
- Insertion
Storage Temperature
- Product Should Be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)
Switch Point Range
- Gases:0.25 to 200 sfps, 0.08 to 60 SMPS - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
- Hydrocarbon-based Liquids: 0.01 to 5.0 FPS, 0.003 to 1.50 MPS
- Water-based Liquids: 0.01 to 3.00 FPS, 0.003 to 0.9 MPS
Switch Type
- SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Maximum
Wetted Materials
- 316, 316L Stainless Steel
- All-Welded Construction
- Hastelloy® C-276
- Titanium
Documentation
Data Sheets
Product Manuals
Application Considerations
Application Notes
- Application Note - Kayden 4-20mA Analog Output pdf 766 KB
- Application Note - Kayden Acid Level Detection pdf 1.4 MB
- Application Note - Kayden Fail Safe pdf 894 KB
- Application Note - Kayden High Level Detection Holding Tank pdf 996 KB
- Application Note - Kayden Leak Detection pdf 1.5 MB
- Application Note - Kayden Monitoring Digester Flow pdf 831 KB
- Application Note - Kayden Oil Water Separation pdf 1.2 MB
- Application Note - Kayden Pulp and Paper Digester Tank pdf 1.1 MB
- Application Note - Kayden Pulp and Paper Skimmer Tank pdf 829 KB
- Application Note - Kayden Pump Monitoring and Protection pdf 1.0 MB
- Application Note - Kayden Pump Monitoring and Protection Remote pdf 1.2 MB
Catalogs
Certifications & Approvals
Outline Drawings
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing F: Local Enclosure 2" MNPT pdf 312 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing H: Remote Enclosure 3/4" MNPT pdf 720 KB
- 2020 Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing A - Local Enclosure ½" MNPT pdf 190 KB
- 2020 Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing B - Local Enclosure 3/4" MNPT pdf 194 KB
- 2020 Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing C - Local Enclosure 1" MNPT pdf 181 KB
- 2020 Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing D - Local Enclosure 1 1/4" MNPT pdf 187 KB
- 2020 Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing E - Local Enclosure 1 1/2" MNPT pdf 188 KB
- 2020 Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing F - Local Enclosure 2" MNPT pdf 221 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing A: Local Enclosure 1/2" MNPT pdf 330 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing B: Local Enclosure 3/4" MNPT pdf 321 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing C: Local Enclosure 1" MNPT pdf 315 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing D: Local Enclosure 1-1/4" MNPT pdf 311 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing E: Local Enclosure 1-1/2" MNPT pdf 321 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing G: Remote Enclosure 1/2" MNPT pdf 738 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing I: Remote Enclosure 1" MNPT pdf 721 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing J: Remote Enclosure 1-1/4" MNPT pdf 714 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing K: Remote Enclosure 1-1/2" MNPT pdf 718 KB
- Legacy Outline Dimension Drawing - Kayden CLASSIC 810 - Drawing L: Remote Enclosure 2" MNPT pdf 723 KB