Images are representations only.

PT-500 Pressure Transmitter

Brand: Automation Products Group Inc. (APG)
The PT-500 is a rugged submersible pressure transmitter designed for tank liquid level measurement, water and wastewater applications, and well depth measurement.
Features
  • Simple to install 
  • High precision, solid state signal: 4-20 mA 
  • Exclusive, removable and reusable cage 
  • 1/2" Male NPT option on cable end for use with conduit 
  • Durable transducer face 
  • Instrinsically safe for Class 1, Div 1/Zone 0 (4-20 mA only) 
  • Built-in lightning protection on every model  
show more

The Part Numbers & SKUs listed below have been added to Stores by Sellers, but they have not yet listed a price or inventory. Find the Part Number & SKUs you're looking for and request a quote from any of the affiliated Sellers!

1 - 48 of 302 Part Numbers
PT-500-1.5-PSIG-L1-E0-P1-5-N0-AC2
PT-500-1.5-PSIG-L1-E0-P1-5-N0-AC2
APG PT-500 Submersible Transducer, 0-1.5 psi, 5-ft Cable, 1/2"MNPT Nose Cone, 4-20 mA
PT-500-1.5-PSIG-L1-P1-5
PT-500-1.5-PSIG-L1-P1-5
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-1.5 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 5' Cable (Polyurethane-Blue)

Overview

  • PT-500: Submersible Liquid Level Transducer
    • Cable Type: Blue Polyurethane (with vent tube)

  • 1.5-PSIG: Pressure Range: 0 to 1.5 PSIG
  • L1: Output: 4-20 mA
  • (E0): 1/2” NPTM fitting for conduit, with pigtail
  • P1: Process Connection: 1/2” NPTM with removable plastic nose cone
  • 5: Cable Length:  5 Feet
  • (N0):  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel



Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-100-KPAG-L1-E0-P38-40-N0-AC2
PT-500-100-KPAG-L1-E0-P38-40-N0-AC2
APG PT-500 Submersible Transducer, 0-100 kPa, 40-ft Cable, 1-1/2" Tri-Clover,3/4"Diaphragm,4-20 mA
PT-500-100-KPAG-L1-P38-40
PT-500-100-KPAG-L1-P38-40
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-100 kPa (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection, +/-0.25% Accuracy, 40' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 100-KPAG = Pressure Range: 0 to 100 KPAG
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P38 = 1-1/2” tri-clover with 3/4” diaphragm
  • 40 = Cable Length:  40 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel



Cable: Polyurethane



Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-FTH2OG-L1-E0-P39-25-N0-AC2
PT-500-10-FTH2OG-L1-E0-P39-25-N0-AC2
APG PT-500 Submersible Transducer,0-10-ft H2O,25-ftCable,1-1/2"Tri-Clover,3/4"Diaphragm,Cage,4-20 mA
PT-500-10-FTH2OG-L1-P39-25
PT-500-10-FTH2OG-L1-P39-25
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 FTH2O (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 25' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-FTH2OG = Pressure Range: 0 to 10 Feet H2O, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P39 = Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 25 = Cable Length:  25 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel



Cable: Polyurethane



Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-FTH2O-L1-E0-P38-60-N0-AC2
PT-500-10-FTH2O-L1-E0-P38-60-N0-AC2
APG PT-500 Submersible Transducer,0-10-ft H2O, 60-ft Cable, 1-1/2" Tri-Clover, 3/4"Diaphragm,4-20 mA
PT-500-10-FTH2O-L1-P38-60
PT-500-10-FTH2O-L1-P38-60
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 FTH2O (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection, +/-0.25% Accuracy, 60' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-FTH2O = Pressure Range: 0 to 10 Feet H2O, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P38 = Process Connection: 1-1/2” tri-clover with 3/4” diaphragm
  • 60 = Cable Length:  60 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin

CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10K-MMH2O-L1-E0-P39-83-N0-AC2
PT-500-10K-MMH2O-L1-E0-P39-83-N0-AC2
APG PT-500 Submersible Transducer,10k mmH2O, 83-ft Cable, 1-1/2"Tri-Clover 3/4" Diaph, Cage, 4-20 mA
PT-500-10K-MMH2O-L1-P39-83
PT-500-10K-MMH2O-L1-P39-83
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10,000 MMH2O (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 83' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10K-MMH2O = Pressure Range: 0 to 10,000 mm/H2O
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P39 = Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 83 = Cable Length:  83 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel



Cable: Polyurethane



Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-E0-P1-15-N0-AC2
PT-500-10-PSIG-L1-E0-P1-15-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 15-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-17-N0-AC2
PT-500-10-PSIG-L1-E0-P1-17-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 17-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-20-N0-AC2
PT-500-10-PSIG-L1-E0-P1-20-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 20-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-27-N0-AC2
PT-500-10-PSIG-L1-E0-P1-27-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 27-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-2-N0
PT-500-10-PSIG-L1-E0-P1-2-N0
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 2' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • E0 = 1/2” NPTM fitting for conduit, with pigtail
  • P1 = Process Connection: 1/2” NPTM with removable plastic nose cone
  • 2 = Cable Length:  2 Feet
  • N0 =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-E0-P1-2-N0-AC2
PT-500-10-PSIG-L1-E0-P1-2-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 2-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-30-N0-AC2
PT-500-10-PSIG-L1-E0-P1-30-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 30-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-40-N0
PT-500-10-PSIG-L1-E0-P1-40-N0
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 40' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P1 = Process Connection: 1/2” NPTM with removable plastic nose cone
  • 40 = Cable Length:  40 Feet
  • (N0) =  ±0.25% Accuracy



Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-E0-P1-40-N0-AC2
PT-500-10-PSIG-L1-E0-P1-40-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 40-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-60-N0-AC2
PT-500-10-PSIG-L1-E0-P1-60-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 60-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P1-82-N0-AC2
PT-500-10-PSIG-L1-E0-P1-82-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 82-ft Cable, 1/2" MNPT Nose Cone, 4-20 mA
PT-500-10-PSIG-L1-E0-P38-60-N0-AC2
PT-500-10-PSIG-L1-E0-P38-60-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 60-ft Cable, 1-1/2"Tri-Clover,3/4"Diaphragm,4-20 mA
PT-500-10-PSIG-L1-E0-P39-100-N0-AC2
PT-500-10-PSIG-L1-E0-P39-100-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi,100-ft Cable,1-1/2"Tri-Clover,3/4"Diaphragm,Cage,4-20 mA
PT-500-10-PSIG-L1-E0-P39-33-N0-AC2
PT-500-10-PSIG-L1-E0-P39-33-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 33-ft Cable,1-1/2"Tri-Clover,3/4"Diaphragm,Cage,4-20 mA
PT-500-10-PSIG-L1-E0-P39-3-N0-AC2
PT-500-10-PSIG-L1-E0-P39-3-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 3-ft Cable, 1-1/2"Tri-Clover,3/4"Diaphragm,Cage,4-20 mA
PT-500-10-PSIG-L1-E0-P39-40-N0-AC2
PT-500-10-PSIG-L1-E0-P39-40-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 40-ft Cable,1-1/2"Tri-Clover,3/4"Diaphragm,Cage,4-20 mA
PT-500-10-PSIG-L1-E0-P39-40-N0-B0
PT-500-10-PSIG-L1-E0-P39-40-N0-B0
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 40' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P39 = Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 40 = Cable Length:  40 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-E0-P39-60-N0
PT-500-10-PSIG-L1-E0-P39-60-N0
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 60' Cable (Polyurethane-Blue)

Overview

  • PT-500: Submersible Liquid Level Transducer
    • Cable Type: Blue Polyurethane (with vent tube)

  • 10-PSIG: Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1: Output: 4-20 mA
  • (E0): 1/2” NPTM fitting for conduit, with pigtail
  • P39: Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 60: Cable Length:  60 Feet
  • (N0): ±0.25% Accuracy



Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-E0-P39-60-N0-AC2
PT-500-10-PSIG-L1-E0-P39-60-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 60-ft Cable,1-1/2" NPT Tri-Clover, Cage, 4-20 mA
PT-500-10-PSIG-L1-E0-P39-66-N0
PT-500-10-PSIG-L1-E0-P39-66-N0
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 66' Cable (Polyurethane-Blue)

Overview

  • PT-500: Submersible Liquid Level Transducer
    • Cable Type: Blue Polyurethane (with vent tube)

  • 10-PSIG: Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1: Output: 4-20 mA
  • (E0): 1/2” NPTM fitting for conduit, with pigtail
  • P39: Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 66: Cable Length:  66 Feet
  • (N0): ±0.25% Accuracy



Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Protective Cone: Delrin

CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-E0-P39-66-N0-AC2
PT-500-10-PSIG-L1-E0-P39-66-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 66-ft Cable,1-1/2" NPT Tri-Clover, Cage, 4-20 mA
PT-500-10-PSIG-L1-E0-P39-82-N0-AC2
PT-500-10-PSIG-L1-E0-P39-82-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 82-ft Cable,1-1/2"Tri-Clover,3/4"Diaphragm,Cage,4-20 mA
PT-500-10-PSIG-L1-P1-15
PT-500-10-PSIG-L1-P1-15
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 15' Cable (Polyurethane-Blue)

Overview

  • PT-500: Submersible Liquid Level Transducer
    • Cable Type: Blue Polyurethane (with vent tube)

  • 10-PSIG: Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1: Output: 4-20 mA
  • P1: Process Connection: 1/2” NPTM with removable plastic nose cone
  • 15: Cable Length:  15 Feet

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin

CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P1-17
PT-500-10-PSIG-L1-P1-17
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 17' Cable (Polyurethane-Blue)

Overview

  • PT-500: Submersible Liquid Level Transducer
    • Cable Type: Blue Polyurethane (with vent tube)

  • 10-PSIG: Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1: Output: 4-20 mA
  • (E0): 1/2” NPTM fitting for conduit, with pigtail
  • P1: Process Connection: 1/2” NPTM with removable plastic nose cone
  • 17: Cable Length:  17 Feet
  • (N0):  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel



Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P1-20
PT-500-10-PSIG-L1-P1-20
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 20' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P1 = Process Connection: 1/2” NPTM with removable plastic nose cone
  • 20 = Cable Length:  20 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P1-27
PT-500-10-PSIG-L1-P1-27
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 27' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P1 = Process Connection: 1/2” NPTM with removable plastic nose cone
  • 27 = Cable Length:  27 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P1-30
PT-500-10-PSIG-L1-P1-30
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 30' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P1 = Process Connection: 1/2” NPTM with removable plastic nose cone
  • 30 = Cable Length:  30 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin

CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P1-40
PT-500-10-PSIG-L1-P1-40
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 40' Cable (Polyurethane-Blue)
PT-500-10-PSIG-L1-P1-60
PT-500-10-PSIG-L1-P1-60
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 60' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P1 = Process Connection: 1/2” NPTM with removable plastic nose cone
  • 60 = Cable Length:  60 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P1-82
PT-500-10-PSIG-L1-P1-82
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 82' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P1 = Process Connection: 1/2” NPTM with removable plastic nose cone
  • 82 = Cable Length:  82 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P38-60
PT-500-10-PSIG-L1-P38-60
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection, +/-0.25% Accuracy, 60' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P38 = Process Connection: 1-1/2” tri-clover with 3/4” diaphragm
  • 60 = Cable Length:  60 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P39-100
PT-500-10-PSIG-L1-P39-100
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 100' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P39 = Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 100 = Cable Length:  100 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P39-3
PT-500-10-PSIG-L1-P39-3
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 3' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P39 = Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 3 = Cable Length:  3 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin

CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P39-33
PT-500-10-PSIG-L1-P39-33
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 33' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P39 = Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 33 = Cable Length:  33 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P39-60
PT-500-10-PSIG-L1-P39-60
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 60' Cable (Polyurethane-Blue)

Overview

  • PT-500: Submersible Liquid Level Transducer
    • Cable Type: Blue Polyurethane (with vent tube)

  • 10-PSIG: Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1: Output: 4-20 mA
  • (E0): 1/2” NPTM fitting for conduit, with pigtail
  • P39: Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 60: Cable Length:  60 Feet
  • (N0): ±0.25% Accuracy



Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L1-P39-82
PT-500-10-PSIG-L1-P39-82
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), 4-20 mA Output, 1/2" MNPT Electrical Connection, 1-1/2" Tri-Clover with 3/4" Diaphragm Process Connection (Protective Cage), +/-0.25% Accuracy, 82' Cable (Polyurethane-Blue)

Overview

  • PT-500 = Submersible Liquid Level Transducer
    • Cable Type = Blue Polyurethane (with vent tube)

  • 10-PSIG = Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L1 = Output: 4-20 mA
  • (E0) = 1/2” NPTM fitting for conduit, with pigtail
  • P39 = Process Connection: 1-1/2” Tri-Clover with Protective Sensor Cage
  • 82 = Cable Length:  82 Feet
  • (N0) =  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin


CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L5-E0-P1-50-N0
PT-500-10-PSIG-L5-E0-P1-50-N0
APG PT-500 Series Submersible Liquid Level Transmitter, Intrinsically Safe, 0-10 psi (Gauge), RS-485 (Modbus) Output, 1/2" MNPT Electrical Connection, 1/2" MNPT Process Connection (Nose Cone), +/-0.25% Accuracy, 50' Cable (Polyurethane-Blue)

Overview

  • PT-500: Submersible Liquid Level Transducer
    • Cable Type: Blue Polyurethane (with vent tube)

  • 10-PSIG: Pressure Range: 0 to 10 PSI, Gauge Pressure
  • L5:Output: Modbus RTU, 4-wire RS-485. Field Adjustable Zero feature is not included.
  • (E0): 1/2” NPTM fitting for conduit, with pigtail
  • P1: Process Connection: 1/2” NPTM with removable plastic nose cone
  • 50: Cable Length:  60 Feet
  • (N0):  ±0.25% Accuracy

Supply Voltage: 10-28 VDC

Temperature Range: Compensated: -17°C to +54°C (+0°F to +130°F)

Materials of Construction:

Housing: 316L Stainless Steel

Cable: Polyurethane

Protective Cone: Delrin

CSA Exia Class I, Division I;  Groups C,D T4. Class I, Zone 0, Group IIB
PT-500-10-PSIG-L5-E0-P1-50-N0-AC2
PT-500-10-PSIG-L5-E0-P1-50-N0-AC2
APG PT-500 Submersible Transducer, 0-10 psi, 50-ft Cable, 1/2" MNPT Nose Cone, MODBUS
1 - 48 of 302 Part Numbers

PT-500

Cable Type

Pressure Range

Output Format

  • view details
  • view details

Cable Entry

Process Connection

  • view details

Accuracy

Cable Length

Cable Length

Cable Length

Cable Length

Specifications

Accuracy

  • ≤ 0.5% BFSL

Approvals & Certifications

  • CSA Class I, Division 1, Groups C, D

Compensated Temperature

  • -17° to 54° C (0° to 130° F)

Display

  • None

Electrical Connectors

  • Waterproof Pigtail with Overmolded Cable

Enclosure, Body Material

  • Delrin® Cone

Input Power

  • Vdc: 10-28

Maximum System Pressure

  • Submersible up to 450 feet (137 m)

NPT Connection

  • 1/2" NPT Male

Output

  • 0-10 Vdc
  • 0-5 Vdc
  • 4-20 mA

Pressure Range

  • bar: 0.07 to 20.68
  • kPa: 6.7 to 2,068
  • psi: 1 to 300

Reverse Polarity Protection

  • Protected Against Reverse Polarity, Surge, Per IEC 61000-4-5

Span & Zero Effect

  • ≤ 0.025% of Full Scale Output/°F at 21° C (70° F)

Tri-Clamp Connection

  • 1-1/2" Tri-Clamp

Wetted Materials

  • 316L Stainless Steel
The PT-500 is a rugged submersible pressure transmitter designed for tank liquid level measurement, water and wastewater applications, and well depth measurement.
Features
  • Simple to install 
  • High precision, solid state signal: 4-20 mA 
  • Exclusive, removable and reusable cage 
  • 1/2" Male NPT option on cable end for use with conduit 
  • Durable transducer face 
  • Instrinsically safe for Class 1, Div 1/Zone 0 (4-20 mA only) 
  • Built-in lightning protection on every model