Images are representations only.

Kayden CLASSIC® 810 Flow, Level, Interface Switch & Transmitter

Brand: Kayden Instruments
The Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter features a precision welded, highly accurate stainless steel sensor. Ideal for liquids, gases & slurries in a clean or dirty process, and is available in a wide range of thread sizes and insertion lengths.

All Kayden models feature a rugged flameproof enclosure with blind or lens covers available. Kayden’s advanced digital electronics will revolutionize the way you monitor and control your process. 

  • Process Connections - Male NPT
    • 1/2"
    • 3/4"
    • 1"
    • 1-1/4"
    • 1-1/2"
    • 2"
  • Adjustable Set Point Range
    • 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Lengths
    • 1.2" (3.0 cm)
    • 2" (5.0 cm)
    • 3" (7.5 cm)
    • 4" (10.1 cm)
    • 6" (15.2 cm)
    • 9" (22.8 cm)
    • 12" (30.4 cm)
    • 18" (45.7 cm)
    • Custom Lengths from 2.5" to 120" (6.0 cm to 305 cm) by 1/2" (1 cm) increments
  • Input/Supply Power
    • 12-24 Vdc & 120-240 Vac, 50-60 Hz
  • Operating Pressure (Maximum)
    • CSA & FM: 3480 psi, 24,000 kPa, 240 bar
    • CRN - 316/316L Stainless Steel - Canadian Registration Number 0F20731.5C: 2053 psi, 14,155 kPa, 142 bar
    • CRN - Titanium - Canadian Registration Number 0F20731.5C: 1165 psi, 8033 kPa, 81 bar
    • CRN - Hastelloy® C-276 - Canadian Registration Number 0F20731.5C: 2290 psi, 15,790 kPa, 158 bar
  • Temperature Range (Sensor)
    • -45° to 200° C, -50° to 392° F
  • Local Enclosure
    • Aluminum Flameproof
    • 1" Female NPT
    • NEMA 4X, IP55 / IP67
  • Local Enclosure Cover
    • Blind or Glass Lens
    • Flameproof
  • Wetted Materials
    • 316/316L Stainless Steel
    • Titanium
    • Hastelloy® C-276
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA
    • Modbus
    • Rated 120 Vac max, 30 Vdc max, 4A max
  • Approvals
    • FM
    • CSA
    • CRN
    • Single Seal
    • NACE
    • ASME BPVC Sec. VIII Div. 1
show more

The Part Numbers & SKUs listed below have been added to Stores by Sellers, but they have not yet listed a price or inventory. Find the Part Number & SKUs you're looking for and request a quote from any of the affiliated Sellers!

1 - 48 of 788 Part Numbers
810-RAC-0010-C1G0A3E
810-RAC-0010-C1G0A3E
810-RAC-0012-C1B0A1E
810-RAC-0012-C1B0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.05 cm. 
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0012-C1B0A3E
810-RAC-0012-C1B0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.05 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0012-C1B0A9E
810-RAC-0012-C1B0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.05 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0012-C1B1B1E
810-RAC-0012-C1B1B1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Remote Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Blind Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0012-C1B1G1E
810-RAC-0012-C1B1G1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Glass Lens Cover - Flameproof
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0012-C1B1G9E
810-RAC-0012-C1B1G9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0012-C1G0A1E
810-RAC-0012-C1G0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.05 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from ayden.com

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0012-C1G0A3E
810-RAC-0012-C1G0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.05 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0012-C1G0A9E
810-RAC-0012-C1G0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 1.2", 3.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0020-C1B0A1E
810-RAC-0020-C1B0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0020-C1B0A3E
810-RAC-0020-C1B0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.08 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0020-C1B0A9E
810-RAC-0020-C1B0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4



 
810-RAC-0020-C1B1B1E
810-RAC-0020-C1B1B1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Remote Electronics Enclosure with Blind Cover, c c CSA us (UL Standards) us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1224 psi, 8439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F 
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Blind Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0020-C1B1G1E
810-RAC-0020-C1B1G1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: c c CSA us (UL Standards) us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1224 psi, 8439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F 
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810RAC-0020-C1B1G3E
810RAC-0020-C1B1G3E
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus,1/2" NPT,2"U, SST,Remote,Blind, CSA/CRN
810-RAC-0020-C1B1G3E
810-RAC-0020-C1B1G3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.0 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1224 psi, 8439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F 
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0020-C1G0A1E
810-RAC-0020-C1G0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.08 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0020-C1G0A3E
810-RAC-0020-C1G0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.08 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0020-C1G0A9E
810-RAC-0020-C1G0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 2", 5.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0030-C1B0A1E
810-RAC-0030-C1B0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 3"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 3", 7.5 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0030-C1B0A3E
810-RAC-0030-C1B0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 3"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 3", 7.5 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0030-C1B0A9E
810-RAC-0030-C1B0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 3"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 3", 7.5 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0030-C1B1G3E
810-RAC-0030-C1B1G3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 3"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 3" 7.5 cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1224 psi, 8439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F 
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0030-C1G0A1E
810-RAC-0030-C1G0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 3"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 3", 7.5 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0030-C1G0A3E
810-RAC-0030-C1G0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 3"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 3", 7.5 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0040-C1B0A1E
810-RAC-0040-C1B0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0040-C1B0A3E
810-RAC-0040-C1B0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0040-C1B0A9E
810-RAC-0040-C1B0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0040-C1B1B1E
810-RAC-0040-C1B1B1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Remote Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F 
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Blind Cover
  • Wetted Materials:
  • Standard: 316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0040-C1B1B9E
810-RAC-0040-C1B1B9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Remote Electronics Enclosure with Blind Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Blind Cover
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0040-C1B1G1E
810-RAC-0040-C1B1G1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -55°C to 200°C, -67°F to 392°F  
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0040-C1B1G3E
810-RAC-0040-C1B1G3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe Width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F  
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0040-C1G0A1E
810-RAC-0040-C1G0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0040-C1G0A3E
810-RAC-0040-C1G0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0040-C1G0A9E
810-RAC-0040-C1G0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 4", 10.1 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0060-C1B0A1E
810-RAC-0060-C1B0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0060-C1B0A3E
810-RAC-0060-C1B0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0060-C1B0A9E
810-RAC-0060-C1B0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0060-C1B1B3E
810-RAC-0060-C1B1B3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Remote Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F 
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Blind Cover
  • Wetted Materials:
  • Standard: 316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0060-C1B1B9E
810-RAC-0060-C1B1B9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Remote Electronics, Local Electronics Enclosure with Blind Cover, Approvals: c CSA us (UL Standards), Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F 
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Blind Cover
  • Wetted Materials:
  • Standard: 316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0060-C1B1G3E
810-RAC-0060-C1B1G3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Remote Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1224 psi, 8439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F  
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Glass Lens Cover
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0060-C1G0A1E
810-RAC-0060-C1G0A1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards)

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24,000 kPa, 240 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4
810-RAC-0060-C1G0A3E
810-RAC-0060-C1G0A3E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: c CSA us (UL Standards), CRN

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4
810-RAC-0060-C1G0A9E
810-RAC-0060-C1G0A9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: FM

Overview

  • Process Connections: 1/2" MNPT
  • Insertion 'U' Length: 6", 15.2 cm
  • Probe width: 0.69", 1.75cm
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 1,224 psi, 8,439 kPa, 84.4 bar
  • Temperature Range (Sensor): -45°C to 200°C, -49°F to 392°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316/316L Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)

  • Electronics - Standard Features:
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)

    • Temperature Compensation
    • Start-Up Bypass Timer

  • FM, NACE, NEMA 4
810-RAC-0090-C1B0A1E
810-RAC-0090-C1B0A1E
810-RAC-0090-C1B0A9E
810-RAC-0090-C1B0A9E
810-RAC-0090-C1B1G3E
810-RAC-0090-C1B1G3E
1 - 48 of 788 Part Numbers

CLASSIC® 810

Sensor Material

Process Connection - Male NPT

Insertion 'U' Length

  • view details
  • view details

Cover for Local Enclosure

Remote Electronics Enclosure & Cover

Agency Approvals

Specifications

Accuracy

  • Flow Service: ± 1.0% of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
  • Level Service: ± 0.64 cm (0.25")

Applications

  • Flow
  • Interface
  • Level

Approvals & Certifications

  • CRN - 316, 316L Stainless Steel - Canadian Registration Number 0F20731.5C: 2053 psi, 14,155 kPa, 142 bar
  • CRN - Hastelloy® C-276 - Canadian Registration Number 0F20731.5C: 2290 psi, 15,790 kPa, 158 bar
  • CRN - Titanium - Canadian Registration Number 0F20731.5C: 1165 psi, 8033 kPa, 81 bar
  • CSA - Local (Sensor) Enclosure Flameproof: Class I, Division 1, Groups B, C, D, Ex D IIB + H2 AEx D IIB + H2 (Class I, Zone 1, Group IIB + H2) Temperature Code: T3 Enclosure Typical 4 / IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex D IIB + H2 AEx D IIB + H2 (Class I, Zone 1, Groups IIB + H2) Temperature Code: T3
  • FM - Local (Sensor) Enclosure Flameproof: Class I, Division 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx D IIB + H2 Enclosure Typical 4/IP55
  • FM - Remote Electronics Enclosure - Optional Flameproof: Class I, Division 1, Groups B, C, D Temperature Codes: T2D (Ta=75° C), T3 (Ta=65° C) Class I, Zone 1, AEx D IIB + H2 Enclosure Typical 4/IP55

Communication

  • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
  • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

Cover - for Local Enclosure

  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Electronics - Standard Features

  • *Configurable only from the Kayden RCM Software
  • 100% Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out*
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5% Steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

Enclosure Finish

  • Powder-Coated Polyester TGIC

Enclosure, Body Details

  • 1" NPT Female Conduit Connection
  • Buna-N O-Ring on Cover

Enclosure, Body Material

  • Copper-Free Aluminum (Does Not Exceed 0.4% Copper)

Environmental Protection

  • IP55
  • IP67
  • NEMA 4X

Input Power

  • 12-24 Vdc, 120-240 Vac, 50/60 Hz
  • Power Consumption: Maximum
  • Universal Power Input

Insertion 'U' Length

  • 1.2" (3 cm)
  • 12" (30 cm)
  • 18" (46 cm)
  • 2" (5 cm)
  • 3" (7.5 cm)
  • 4" (10.1 cm)
  • 6" (15.2 cm)
  • 9" (23 cm)
  • Custom 'U' Lengths 2.5" to 120" (6.4 cm to 305 cm) Available in 1/2" (1.0 cm) Increments.

NPT Connection

  • 1" NPT Male
  • 1/2" NPT Male
  • 1-1/2" NPT Male
  • 1-1/4" NPT Male
  • 2" NPT Male
  • 3/4" NPT Male

Operating Pressure - Sensor

  • CRN - All Process Connections - 316/316 Stainless Steel - Canadian Registration Number 0F20731.5C: Maximum
  • CRN - All Process Connections - Hastelloy® C-276 - Canadian Registration Number 0F20731.5C: Maximum
  • CRN - All Process Connections - Titanium - Canadian Registration Number 0F20731.5C: Maximum
  • CSA - All Process Connections: Maximum

Operating Temperature - Electronics

  • -55° to 65° C (-67° to 149° F)

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Output

  • 4-20 mA (Thermal Signal, Scaleable) 120 Vac, Maximum

Principle of Operation

  • Thermal, Calorimetric

Remote Control & Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 & 2
  • Load or Save User Settings
  • Lock or Unlock the Display Panel to Protect the Settings
  • Many Other Adjustable Features
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated Via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process Via the Graphical Display

Remote Electronics Enclosure & Cover

  • Blind Cover - Flameproof
  • Glass Lens Cover - Flameproof

Response Time

  • Approximately 0.5 to 30 seconds

Sensor, Probe Style

  • Insertion

Storage Temperature

  • Product Should Be Stored in a Clean & Dry Environment between -30° & 60° C (-22° & 140° F)

Switch Point Range

  • Gases:0.25 to 200 sfps, 0.08 to 60 SMPS - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
  • Hydrocarbon-based Liquids: 0.01 to 5.0 FPS, 0.003 to 1.50 MPS
  • Water-based Liquids: 0.01 to 3.00 FPS, 0.003 to 0.9 MPS

Switch Type

  • SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Maximum

Wetted Materials

  • 316, 316L Stainless Steel
  • All-Welded Construction
  • Hastelloy® C-276
  • Titanium
The Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter features a precision welded, highly accurate stainless steel sensor. Ideal for liquids, gases & slurries in a clean or dirty process, and is available in a wide range of thread sizes and insertion lengths.

All Kayden models feature a rugged flameproof enclosure with blind or lens covers available. Kayden’s advanced digital electronics will revolutionize the way you monitor and control your process. 

  • Process Connections - Male NPT
    • 1/2"
    • 3/4"
    • 1"
    • 1-1/4"
    • 1-1/2"
    • 2"
  • Adjustable Set Point Range
    • 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Lengths
    • 1.2" (3.0 cm)
    • 2" (5.0 cm)
    • 3" (7.5 cm)
    • 4" (10.1 cm)
    • 6" (15.2 cm)
    • 9" (22.8 cm)
    • 12" (30.4 cm)
    • 18" (45.7 cm)
    • Custom Lengths from 2.5" to 120" (6.0 cm to 305 cm) by 1/2" (1 cm) increments
  • Input/Supply Power
    • 12-24 Vdc & 120-240 Vac, 50-60 Hz
  • Operating Pressure (Maximum)
    • CSA & FM: 3480 psi, 24,000 kPa, 240 bar
    • CRN - 316/316L Stainless Steel - Canadian Registration Number 0F20731.5C: 2053 psi, 14,155 kPa, 142 bar
    • CRN - Titanium - Canadian Registration Number 0F20731.5C: 1165 psi, 8033 kPa, 81 bar
    • CRN - Hastelloy® C-276 - Canadian Registration Number 0F20731.5C: 2290 psi, 15,790 kPa, 158 bar
  • Temperature Range (Sensor)
    • -45° to 200° C, -50° to 392° F
  • Local Enclosure
    • Aluminum Flameproof
    • 1" Female NPT
    • NEMA 4X, IP55 / IP67
  • Local Enclosure Cover
    • Blind or Glass Lens
    • Flameproof
  • Wetted Materials
    • 316/316L Stainless Steel
    • Titanium
    • Hastelloy® C-276
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA
    • Modbus
    • Rated 120 Vac max, 30 Vdc max, 4A max
  • Approvals
    • FM
    • CSA
    • CRN
    • Single Seal
    • NACE
    • ASME BPVC Sec. VIII Div. 1

Typical Applications

Flow
  • Pump Protection – Dry Alarm
  • Leak Detection
  • Flow Monitoring & Verification
  • Tank Overflow Protection
  • Flare Gas Monitoring
  • Monitoring Purge Air Flow
  • Lube Oil Systems
  • Vent Monitoring
  • Natural Gas to Boilers
  • Emergency Eye Wash & Shower Stations
  • Drain Line Flow
  • High Pressure Flows
  • Tanker Loading & Unloading
  • Relief Valve & Rupture Disk Flow Monitoring
  • Remote Indication of Flow via Analog Output & Digital Communications
  • Chemical Injection/Additive Flow Monitoring
Level
  • Storage Tanks
  • Oil Separators & Treaters – High, Low & Interface Level
  • Sumps – All Types of fluids ( Water, Oil, etc.)
  • Free Water Knock-out Tanks – High, Low and Interface Level
  • Leak Detection (Accumulation Reservoir)
  • Tank Overflow
  • Sampler Systems
  • Sand Separators
Interface
  • Interface Control in Separation Vessels
  • Interface Detection
  • Interface Control & Level Detection in Settling Vessels
Media
  • Liquids, Air & Gases
  • Hazardous & General-Purpose Areas
  • Slurries
  • Corrosive Liquids

>    IDEAL PROCESS CONDITIONS FOR FLOW    <

Liquids
  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)
  • Recommended minimum of 5 pipe diameters from any disturbance

Air & Gas
  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)
  • Clean and dry

Slurries
  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)

Emulsion
  • Consistent process composition & temperature
  • Sufficient straight run flow profile (minimizes turbulence)
  • Undesirable Process Conditions

>    UNDESIRABLE PROCESS CONDITIONS FOR FLOW    <

Liquids
  • Inconsistent process composition or temperature
  • Insufficient straight run
  • Turbulence
  • Aerated fluids

Air & Gas
  • Inconsistent process composition or temperature
  • Wet or saturated air/gas

Slurries
  • Inconsistent process composition or temperature
  • Insufficient straight run
  • Turbulence
  • Aerated fluids

Emulsion
  • Inconsistent process composition & temperature
  • Insufficient straight run
  • Turbulence
  • Aerated fluids

Solids
  • Dry granulated processes are NOT good candidates for thermal switches

Documentation